Project

General

Profile

Actions

Bug #43

closed

error during calculation with fixed SNR for V or I band

Added by Anonymous over 12 years ago. Updated about 12 years ago.

Status:
Closed
Priority:
High
Assignee:
-
Start date:
2011-10-27
Due date:
% Done:

0%

Estimated time:

Description

Config VIMOS+site ESO, source 'continuum', magnitude 22.5 en V, fixed SNR = 5 en V ou I, j'ai un popup 'there is an error in calculation. See log for details'.

Actions #1

Updated by Anonymous over 12 years ago

  • Status changed from New to Resolved

There was a bug because of which the ETC wasn't respecting the selected option of fixed SNR wavelength (band or value). Because of that the given value was always used, which in the specific case it was zero, resulting in an error of division with zero. Fixed the bug and it will be available in version 0.3.1.

Actions #2

Updated by Anonymous about 12 years ago

  • Status changed from Resolved to Closed

Closing the bug, because the fix is confirmed to work.

Actions

Also available in: Atom PDF