Bug #45
closed
Zero signal for imaging with emission line source
Added by Anonymous about 13 years ago.
Updated almost 13 years ago.
Description
When executing the simulation for imaging, having an emission line as a source, the result signal is zero.
- Status changed from New to Resolved
The method for integrating the source and background fluxes for imaging was using the Romberg algorithm. This algorithm is using the extended trapezoidal rule and because of that it was missing such fluctuations as an emission line. I changed completely the way the calculation of the integral is done for imaging and also the integral for slitless spectroscopy background calculation. Now the internally generated high resolution templates are used, so no flux is lost. This fix will be available in version 0.3.2.
- Status changed from Resolved to Closed
Closing the bug because the fix is confirmed to work from 0.3.2.